Optometry equipment names come up fast when you start working chairside: autorefractor, phoropter, lensometer, keratometer, tonometer, visual field machine, fundus camera, OCT.
This guide maps the instruments an optometric technician uses — what each one measures, who operates it, and how state delegation rules decide that last question.
It is an instrument map, not a buying guide.
Pre-test instruments
Two national documents name this equipment, and both are worth knowing as a technician.
The first is the O*NET task list for ophthalmic medical technicians (SOC 29-2057) — the closest Bureau of Labor Statistics occupation, because BLS has no code for optometric technicians or assistants.
The second is the American Optometric Association's exam outline for its Certified Paraoptometric Technician (CPOT) credential, which spells out the instruments a certified technician is expected to know.
That one occupation groups assistant and technician titles — O*NET's sample titles run from Ophthalmic Assistant to Certified Ophthalmic Surgical Assistant — so the same names double as the ophthalmic technician equipment list.
- Autorefractor — performs refraction automatically. The CPOT outline pairs autorefraction with autokeratometry and covers the reasons autorefractor readings come out wrong.
- Keratometer (ophthalmometer) — measures corneal curvature; O*NET's task line ties the measurement to aiding the diagnosis of conditions such as astigmatism.
- Lensometer — reads the prescription in a client's current eyeglasses; O*NET describes that task under opticians, and lensometry sits on the technician task list too.
- Tomograph — named on the O*NET task list among the instruments technicians operate.
- Visual acuity charts — the outline's acuity items cover Snellen, Allen figures, tumbling E and Landolt C charts; counting fingers, hand motion, light perception and no light perception for very low vision; and pinhole acuity.
- Ocular motility and depth-perception tests — also listed among O*NET's technician tasks.
The first pre-test is not an instrument at all: O*NET lists taking medical histories, and the CPOT outline's case-history items run from chief complaint and pain level through medications, allergies, social history and visual demands.
For where this equipment sits in the working day, and how the title splits from assistant, scribe and ophthalmic tech roles, the optometric technician career guide covers the job end to end.
Pressure and visual field instruments
Tonometry is the pressure check: O*NET's technician task list includes conducting tonometry tests to measure intraocular pressure.
The CPOT outline names four tonometers a technician is expected to run — the non-contact tonometer (NCT), the Tono-Pen, iCare and Goldmann applanation — and expects technicians to disinfect tonometers properly.
Cleaning or sterilizing instruments is on the O*NET task list as well, and tonometer disinfection is where that duty gets its own line in the certification outline.
The second family of instruments here is the automated visual field machine.
Visual field testing is on the O*NET technician task list, and the CPOT outline's coverage is specific:
- 10-2, 24-2 and 30-2 test patterns
- superior lid fields
- Threshold versus SITA Fast strategies
- reliability indices
Being on an exam outline is not a delegation permit.
Oregon's delegation rule, for one, does not let a technician perform the final tonometry for a glaucoma patient — one example of how states draw their own lines, taken up below.
Imaging instruments
Imaging is the third bench, and the CPOT outline includes fundus photography and posterior-segment OCT among the tasks it expects of technicians.
Fundus photography runs on the fundus camera.
Posterior-segment OCT runs separately for the optic nerve and the macula, and the outline includes anterior-segment OCT as well.
Image quality is where imaging technique lives: the outline covers getting quality images and spotting and fixing artifacts.
The outline gives no numeric scan-quality threshold.
Axial length measurement is also on the O*NET task list, alongside the motility and depth-perception testing named in the pre-test lineup.
O*NET writes its task list for the whole occupation — one it defines as assisting ophthalmologists, and one BLS also counts inside offices of optometrists: the same list includes assisting with procedures including surgery and calling patients about post-operative recovery.
That is why this equipment map serves as the ophthalmic technician equipment list too.
Instruments the doctor uses that techs set up
The exam room also holds instruments whose diagnostic work a state may keep with the doctor, and one state's rule shows that line in writing.
Oregon's delegation rule (OAR 852-020-0060) lets optometric physicians delegate non-prohibited tasks to well-trained technicians under direct supervision.
It bars delegating ophthalmoscopy, gonioscopy, final biomicroscopy, final refraction, final prescription or treatment decisions, and final tonometry for a glaucoma patient.
Refraction runs through the phoropter — the FDA's device classification describes the manual refractor (phoropter) as a set of lenses of various powers used to measure refractive error.
O*NET lists operating phoropters among technician tasks, and Oregon's rule still keeps the final refraction with the doctor.
In Oregon, the other barred functions — ophthalmoscopy, gonioscopy, final biomicroscopy — stay with the doctor as well.
Our research did not establish what part of that instrument work technicians do in other states.
O*NET's task list adds the support work around the exam: cleaning or sterilizing instruments, assisting with procedures including surgery, and calling patients about post-operative recovery.
Drops are part of the setup.
The CPOT outline lists instilling and recording diagnostic drops — mydriatics and cycloplegics — as a technician task, O*NET lists giving topical ophthalmic medications, and Oregon's rule allows technicians to instill medication as instructed.
Oregon defines direct supervision as technician work overseen and approved by an optometric physician or MD at the practice site, with an intervention protocol in place.
Exam outlines are not delegation rules
Which instruments a new tech learns first
Our research found no published national order for teaching these instruments — the pace is set practice by practice, inside whatever the state's delegation rules allow.
The shape of the starting work is still readable from the task lists.
Taking medical histories and visual acuity testing sit on the O*NET list, and neither depends on more than the acuity charts.
Among the machines the CPOT outline expects a certified technician to operate are the automated pre-test instruments: the autorefractor and autokeratometer, the non-contact tonometer and the visual field instrument.
Imaging adds a judgment layer: the outline's fundus and OCT items cover getting quality images and spotting and fixing artifacts.
For employers, the order is a staffing decision as much as a training one — choosing which instruments a new hire runs, and under what supervision.
Our hiring hub covers how to hire eye care staff.
Whatever the order at your practice, the map stays short: the pre-test instruments, the tonometers, the visual field machine, the imaging bench, and the doctor's own instruments.
Career information, not medical, licensing or legal advice. Delegation and scope are set state by state, in optometry law and board rules — confirm the current rules with your state's board of optometry before you act on anything above.